• Qualitative Fit Test Results for FFP2 or FFP3 Masks

    Please complete this form for each person being test
  •  
  • The first part of the Sensitivity Test requires spraying as many puffs of Nebuliser A (with Solution A) as is required to find out at what range the subject can taste it. The test subject should then rinse their mouth and wipe their face before completing the final stage of the test

  •  
  • The mask is then replaced by the test subject and checked by the examiner. An initial preloading dose of Nebuliser B (using Solution B) with exactly the same Sensitivity Test Range (ST) result (10,20,30 puffs) followed by ST/2 every 30s using the timer throughout the test sequence

  •  
  • If the test is failed at any point:

    1. Remove the hood
    2. Examine fit of face mask
    3. Remove and inspect mask
    4. Advise wearer to clean palate and wash face
    5. Wait 30 minutes, NO EATING, DRINKING OR SMOKING
    6. Conduct a new sensitivity test and record the result
    7. Conduct a NEW Fit Test with a clean mask
    8. Only re-test once with the same make/model/size of mask