National WHS Standards
SIL Audit Checklist
Date
-
Month
-
Day
Year
Date
Address
Street Address
Street Address Line 2
City
State / Province
Postal / Zip Code
Entry and Exit
Rows
Compliant
Non-compliant
Needs Action
Comments
Walkways and Aisles Width
Standard: All walkways and aisles must have a minimum width of 600 mm for safe access.
Check: Measure all aisles and walkways to confirm 600 mm width and free of obstructions.
Slip-Resistance of Entry/Exit Surfaces
Standard: Surfaces must be slip-resistant in both wet and dry conditions.
Check: Confirm slip-resistant materials used
Handrails and Stair Railings
Standard: Stairways must have a handrail on at least one side, upper rail at 900 mm or higher.
Check: Inspect stairways for railings and handrails; wide staircases may need a central handrail.
Power-Operated Doors
Standard: Fitted with safety features to prevent trapping or striking.
Check: Ensure all power-operated doors have safety devices, e.g., sensors or auto-stop mechanisms.
Emergency Exit Markings and Visibility
Standard: Exits clearly marked with visible signage for emergency exits.
Check: Inspect routes to confirm clear markings, signage, and adequate lighting for visibility.
Work Areas
Rows
Compliant
Non-compliant
Needs Action
Comments
Obstruction-Free Emergency Access
Standard: Pathways to emergency exits must be clear and unobstructed
.
Check:
Verify emergency paths are free of obstructions, especially in high-risk areas
.
Workstations
Rows
Compliant
Non-compliant
Needs Action
Comments
Adjustable Seating and Standing
Standard: Workstations should support seated and standing work with posture-supportive chairs
.
Check: Confirm adjustable seating (height, backrest, tilt); ensure sufficient leg clearance.
Ergonomic Layout
Standard: Workstations must allow workers to maintain a comfortable, upright position.
Check: Verify that workstations are designed to minimize strain.
Handrails and Stair Railings
Standard: Stairways must have a handrail on at least one side, upper rail at 900 mm or higher.
Check: Inspect stairways for railings and handrails; wide staircases may need a central handrail.
Power-Operated Doors
Standard: Fitted with safety features to prevent trapping or striking.
Check: Ensure all power-operated doors have safety devices, e.g., sensors or auto-stop mechanisms.
Emergency Exit Markings and Visibility
Standard: Exits clearly marked with visible signage for emergency exits.
Check: Inspect routes to confirm clear markings, signage, and adequate lighting for visibility.
Floors and Surfaces
Rows
Compliant
Non-compliant
Needs Action
Comments
Floor Inspection and Maintenance
Standard: Regular inspection for slip, trip, or fall hazards; maintenance as needed.
.
Check: Inspect for damaged surfaces, loose mats, exposed cables, and other trip hazards.
Slip-Resistance and Grip Level
Standard: Floor surfaces must have sufficient grip, particularly in wet areas.
Check: Inspect kitchens, bathrooms, and other wet areas for slip-resistant treatments or mats.
Lighting
Rows
Compliant
Non-compliant
Needs Action
Comments
Normal range of tasks and workplaces
Standard: Lighting should meet required lux levels per task, from 160 lux -400
.
Check: Adequate lighting was observed. Additional movable lighting employed if required
Outdoor Lighting
Standard: Adequate lighting after dark required for outdoor paths around the workplace and car parks.
Emergency Lighting
Standard: Emergency lighting must be provided for the safe evacuation of people in the event of an emergency.
.
Check: Emergency torches sighted
Housekeeping
Rows
Compliant
Non-compliant
Needs Action
Comments
General tidiness
Standard: Working areas should be generally clean and tidy
.
Check: Observed general tidiness or engagement of cleaners
Clear and Unobstructed Walkways
Standard: Adequate lighting after dark required for outdoor paths around the workplace and car parks.
Check: Inspect walkways for items blocking paths; remove as necessary.
Waste Management
Standard: Waste containers should be conveniently located and regularly emptied.
Check: Confirm accessible waste disposal areas and ensure they are not overflowing.
Ventilation
Rows
Compliant
Non-compliant
Needs Action
Comments
Ventilation and Air Quality
Standard: Workplaces should be ventilated with fresh air, free from contaminants.
.
Check: Confirm adequate ventilation through windows or mechanical systems, with 5% open space.
Air-Conditioning and Filtration
Standard: Systems must be serviced regularly for efficient air flow and contaminant reduction as per manufacturers instructions
Check: Inspect service records for ventilation systems, including air-conditioning filter maintenance.
Thermal Comfort (Heat and Cold)
Rows
Compliant
Non-compliant
Needs Action
Comments
Temperature Range for Comfort
Standard: Indoor temperature should be maintained between 20–26°C
.
Cooling and Heating Measures
Standard: Provide devices like fans, heaters, or shaded areas for extreme temperatures.
Check: Verify cooling/heating devices are functional and appropriately located.
Access to Facilities
Rows
Compliant
Non-compliant
Needs Action
Comments
Accessible Facility Design
Standard: Facilities must be accessible for all workers, including those with disabilities
.
Check: Confirm adequate ventilation through windows or mechanical systems, with 5% open space.
Breaks for Facility Access
Standard: Workers should have access to use facilities as needed.
Check: Verify that workers have reasonable distance access to facilities.
Drinking Water
Rows
Compliant
Non-compliant
Needs Action
Comments
Provision of Clean Drinking Water
Standard: Drinking water must be clean, accessible, and free of charge, located near strenuous work areas and separate from contaminants
Check: Confirm adequate ventilation through windows or mechanical systems, with 5% open space.
Hygienic Dispensing of Water
Standard: Water should be dispensed hygienically, without direct contact with a shared container.
Check: Verify drinking fountains or individual disposable containers are available for water dispensing.
Toilets
Rows
Compliant
Non-compliant
Needs Action
Comments
Toilet Accessibility and Cleanliness
Standard: Provide clean toilets accessible to all workers.
.
Check: Confirm clean and accessible toilets are available, with adequate facilities for different genders as required.
Design of Toilets
Standard: Toilets should be: − fitted with a hinged seat and lid − provided with lighting and ventilation − clearly signposted − fitted with a hinged door capable of locking from the inside on each cubicle − designed to allow emergency access − positioned to ensure privacy for users, and − separated from other rooms by an airlock, a sound-proof wall and a separate entrance that is clearly marked.
Check: Check for privacy, locking mechanisms, lighting, and ventilation in all toilet facilities.
Hygienic Supplies in Toilets
Standard: Provide toilet paper, handwashing facilities, and bins for sanitary items.
Check: Confirm availability of toilet paper, handwashing stations, and sanitary disposal bins for female workers.
Hand Washing
Rows
Compliant
Non-compliant
Needs Action
Comments
Ratio of Handwashing Basins
Standard:
One wash basin per 30 male and one per 30 female workers
.
Check:
Verify adequate number of basins relative to the workforce size.
Design of Handwashing Facilities
Standard:
Hand washing facilities should:
− be accessible at all times to work areas, eating areas and the toilets
− be separate from troughs or sinks used in connection with the work process
− contain both hot and cold water taps or temperature mixers
− be protected from the weather
− be supplied with non-irritating soap preferably from a soap dispenser, and − contain hygienic hand drying facilities, for example automatic air dryers or paper towels
.
Check:
Check for functioning taps, soap dispensers, and hygienic drying options (e.g., air dryers, paper towels)
.
Alternative for Remote Sites
Standard:
Provide hand wipes, sanitizers, or portable wash stations for remote sites
.
Check:
Confirm alternative hygiene facilities are available for remote or mobile sites
.
Eating Facilities
Rows
Compliant
Non-compliant
Needs Action
Comments
Storage and Food Preparation Facilities
Standard:
Include a sink, utensils, a refrigerator, and an appliance for boiling water
.
Check:
Confirm clean storage, preparation facilities, and vermin-proof rubbish bins are available and maintained.
Personal Storage
Rows
Compliant
Non-compliant
Needs Action
Comments
Secure Storage for Personal Items
Standard:
Provide accessible, secure storage for personal belongings and work tools
.
Check:
Confirm lockers or lockable containers are available, secure, and separate from PPE storage to prevent contamination.
Emergency Procedures
Rows
Compliant
Non-compliant
Needs Action
Comments
Effective Emergency Response
Standard:
Procedures must allow an effective response to emergencies
.
Check:
Ensure emergency response procedures are clear, accessible, and cover various emergency situations (fire, chemical, etc.)
Evacuation Procedures
Standard:
Evacuation procedures must ensure safe evacuation from the workplace
.
Check:
Check that evacuation routes are clearly marked and evacuation procedures are included in the emergency plan.
Notification of Emergency Services
Standard:
Notify emergency services as early as possible in an emergency
.
Check:
Confirm procedures for notifying emergency services are clear and prominently displayed
.
Medical Treatment and Assistance
Standard:
Procedures must provide guidance on medical treatment and assistance
.
Check:
Verify that procedures outline steps for providing medical assistance during emergencies
.
Communication During Emergencies
Standard:
Ensure effective communication between authorised emergency coordinators and workers
.
Check:
Confirm communication plans and roles for coordinators are in place and clearly defined
.
Testing of Emergency Procedures
Standard:
Emergency procedures must be tested regularly to ensure effectiveness
.
Check:
Confirm emergency drills are conducted at least once every 12 months and any issues are documented and addressed
.
Worker Training on Emergency Plan
Standard:
Provide information, training, and instruction on emergency procedures
.
Check:
Ensure workers have received training on emergency procedures and that records of training are kept
.
Preparing Emergency Procedures
Rows
Compliant
Non-compliant
Needs Action
Comments
Role and Responsibility Allocation
Standard:
Allocate specific roles for actions in emergencies to trained individuals
.
Check:
Confirm emergency roles (e.g., area wardens) are assigned and trained, and roles are communicated to all workers.
Safe Place Identification
Standard:
Identify safe places in case of emergency
.
Check:
Confirm the plan includes designated safe places and routes to these locations.
Emergency Site Plan Display
Standard:
Display site plans showing fire equipment, exits, and assembly points
.
Check:
Ensure emergency site plans are displayed prominently and accessible to all workers
.
Emergency Contact Numbers
Standard:
Distribute and display emergency phone numbers, including after-hours contacts
.
Check:
Confirm emergency numbers are displayed and accessible throughout the workplace
.
Evacuation Practice Drills
Standard:
Conduct regular evacuation drills, at least annually
.
Check:
Verify that drills are scheduled, practiced, and any issues are documented and resolved.
Emergency Equipment
Rows
Compliant
Non-compliant
Needs Action
Comments
Emergency Equipment Maintenance
Standard:
Maintain equipment required for emergencies, e.g., spill kits, fire extinguishers
.
Check:
Check that emergency equipment is regularly serviced and functional.
Review of Emergency Procedures
Standard:
Regularly review emergency procedures to ensure relevance and effectiveness.
Check:
Confirm procedures are reviewed and updated to reflect any workplace or hazard changes.
Electrical Safety
Rows
Compliant
Non-compliant
Needs Action
Comments
Cord and Plug Condition
Standard:
Cords and plugs should be undamaged and securely attached
.
Check:
Are cords and plugs free of cuts, frays, and visible damage?
Discoloration
Standard:
Equipment should not show signs of excessive heat or moisture
.
Check:
Is there any discoloration on equipment indicating heat or moisture exposure?
Emergency Site Plan Display
Standard:
Display site plans showing fire equipment, exits, and assembly points
.
Check:
Ensure emergency site plans are displayed prominently and accessible to all workers
.
Ventilation and Covers
Standard:
Vents and covers should be secure and unobstructed
.
Check:
Are covers or guards secure, and ventilation inlets and exhausts free of obstructions?
New Equipment
Standard:
New items should be marked with installation date
.
Check:
Is new equipment visually inspected and marked with a “new-to-service” date if required?
After Repairs or Servicing
Standard:
Test equipment after repairs for safety
.
Check:
Has equipment been checked after repair or servicing before use?
Inspection Records
Standard:
Keep records of inspections and tests
.
Check:
Are records kept for all inspections, including tester name, test date, and next test date?
Qualified Tester
Standard:
Tests conducted by qualified personnel
.
Check:
Are testers qualified or trained to carry out inspection and interpret results?
Tagging and Marking
Rows
Compliant
Non-compliant
Needs Action
Comments
Tagging of Tested Equipment
Standard:
Equipment should be marked if tested
.
Check:
Are tested items tagged with the test date, next due date, and tester initials?
First Aid
Rows
Compliant
Non-compliant
Needs Action
Comments
Design
Standard:
First aid kits can be any size or shape but must:
- be large enough to contain the necessary items
− be immediately identifiable with a white cross on green background prominently displayed on the outside
− contain a list of the contents for that kit, and First aid in the workplace
− be made of material that will protect the contents from dust, moisture and contamination.
Check:
Is the first aid kit designed for portability, durability, and ease of access?
First Aid Kits Availability
Standard:
A first aid kit must be accessible to all workers, including in remote or isolated locations
.
Check:
Is a first aid kit available and accessible to all workers on-site?
Kit Contents
Standard:
Kits should contain supplies for common injuries (e.g., cuts, burns, eye injuries)
.
Check:
Does the kit contain necessary supplies as per risk assessment?
Kit Maintenance
Standard:
Kits should be regularly checked and restocked
.
Check:
Has the kit been checked within the last 12 months, or since last use?
Kit Location
Standard:
Kits should be in a prominent, accessible location close to potential hazards
.
Check:
Is the first aid kit clearly visible and located near higher-risk areas?
First Aid Signage
Standard:
Signage should clearly mark first aid kit and room locations
.
Check:
Is signage clear and compliant with AS 1319–1994 standards?
First Aid Room
Standard:
For workplaces with more than 100 workers, a first aid room is recommended
.
Check:
Is a first aid room available and properly equipped for this site?
Trained First Aiders
Standard:
Adequate number of trained first aiders should be available on-site
.
Check:
Are there trained first aiders present and easily identifiable?
Review of First Aid Procedures
Standard:
First aid procedures should be regularly reviewed and updated
.
Check:
Are procedures reviewed annually or after incidents?
First Aid Training for Workers
Standard:
Workers must know how to access first aid services and kits
.
Check:
Have workers received training or orientation on accessing first aid?
Cleaning and Disposal
Standard:
Contaminated items must be disposed of per state/local regulations
.
Check:
Are procedures in place for proper disposal of contaminated items?
Spills Management
Standard:
Spills of blood/bodily substances must be cleaned with gloves and suitable materials.
Check:
Are materials available for safe spill cleaning, and are protocols known?
Labelling Hazardous Chemicals
Rows
Compliant
Non-compliant
Needs Action
Comments
Hazardous Chemicals
Standard:
Ensure an SDS is available on-site for each hazardous chemical - if used in significant amounts or for non-domestic purposes.
I.e 10L decanted containers
.
Check:
Are SDS documents accessible for each hazardous chemical?
SDS Updates and Reviews
Standard:
Check SDSs for date and update information as necessary.
Check:
Are all SDS documents up-to-date (not older than 5 years)?
Hazardous Chemicals Register
Rows
Compliant
Non-compliant
Needs Action
Comments
Chemicals Register
Standard:
Maintain a register listing each hazardous chemical in use.with SDS sheet- if used in significant amounts or for non-domestic purposes.
I.e 10L decanted containers.
Check:
Is there an up-to-date register of hazardous chemicals?
Register Accuracy
Standard:
Register includes product names, locations, and quantities
.
Check:
Is the register comprehensive and current?
Proper Labeling on Original Containers
Standard:
All hazardous chemicals in original packaging must display clear labels with product name, hazards, and instructions
.
Check:
Are original containers properly labeled?
Labeling on Decanted Chemicals
Standard:
Chemicals transferred to new containers should be labeled with contents
.
Check:
Are decanted chemicals properly labeled?
Separation from Food and Personal Items
Standard:
Ensure that chemicals are stored away from food or personal items
.
Check:
Are chemicals stored separately from food items?
Availability of PPE
Standard:
Appropriate PPE (e.g., gloves, goggles) should be available for handling chemicals
.
Check:
Is PPE available for chemical handling?
Regular Chemical Safety Inspections
Standard:
Schedule regular checks for chemical labeling, storage, and availability of SDS and PPE
.
Check:
Are routine inspections conducted for chemical safety?
Receive a copy of the submission
Submit
Should be Empty: