PSAP Test Your Knowledge
  • Test Your Knowledge

    Are you Pump System Certification (PSAP) Ready?
  •  - -
  • The following sample quiz contains 10 questions that represent the type of questions featured on the PSAP Exam.  This quiz has been designed to help you gauge your understanding and knowledge level of the PSAP content.

    Visit our training website for additional information on PSAP training and preparation resources.

    Provide your name and email and select next to begin the PSAP Test Your Knowledge Quiz.

  • PSAP Knowledge Quiz

  • Download the Formula Reference Sheet.

  • 1.What is the estimated pump efficiency of a flooded suction pump, that is pumping water at 68 °F (20 °C) using the following field measured conditions?

    • Current 71.1 Amps average for three phases;
    • Voltage 482 V average for three phases;
    • Power factor 0.9; 
    • Flow rate 2500 gpm (568 m3/h);
    • Suction pressure 2.8 psi (19.3 kPa);
    • Discharge pressure 29.9 psi (206 kPa);
    • Motor efficiency 93%;
    • VFD efficiency 97%;
    • Suction pipe diameter at pressure measurment 12 in (305 mm);
    • Discharge pipe diameter at pressure measurment 10 in (254 mm);
    • Suction gauge elevation above datum 3.3 ft (1 m),
    • Suction gauge elevation above datum 6.6 ft (2 m);
    • Assume head losses between pressure gauges and pump are negligible.
  • 2. What is the NPSHA for a rotodynamic pump operating in a closed system with the following related conditions:  

    • Liquid level above pump centerline (Impeller datum) 15ft (4.6 m);
    • Suction vessel pressure at top of liquid level 10 psia (69 kPa,a);
    • Head loss between suction vessel and pump suction flange 2.0 ft (0.6 m);
    • Liquid vapor pressure 5.4 psia (37.2 kPa,a);
    • Atmospheric pressure 14.7 psia (101 kPa,a);
    • Liquid specific gravity 0.8;
    • Suction pipe velocity entering pump 10 ft/s (3.05 m/s);
    • Pump flow rate 2500 gpm (568 m3/h);
    • Discharge pressure 50 psig (345 kPa)
  • 8. For a field measured system curve that has 100 ft (30.5 m) of static head and 100 ft (30.5 m) of head loss due to major and minor pipe and fitting losses at a flow rate of 2500 gpm (568 m3/h), what will the system head requirement be if the flow rate is increased to 5000 gpm (1135 m3/h)and the water level suppling the pump decreases by 10 ft (3 m), and everything else remains constant?

  • 9. For a pipeline pump handling jet fuel with specific gravity 0.82 and operating at 1000 gpm (227 m3/h), 2000 ft (610 m) with a overall efficiency of 83%, what is the specific energy consumption?

  • 10. For the measurements below, what is the total head for a centrifugal pump?

    • Flow rate is 700 gpm (160 m3/h),
    • Suction (inlet) pressure is 100 psig (690 kPa)
    • Suction pipe velocity at pressure measurement 5.7 ft/s (1.8 m/s)
    • Discharge (outlet) pressure is 250 psig (1725 kPa)
    • Discharge pipe velocity at pressure measurement 16 ft/s (4.9 m/s)
    • Gauge locations are two pipe diameters before the inlet and two pipe diameters after the outlet
    • Gauges are at the same elevation
    • Fluid specific gravity is 0.8 (800 kg/m3)
    • Atmospheric pressure is 14.5 psi (100 kPa)
    • Acceleration due to gravity is 32.2 ft/s2 (9.81 m/s2)
  • Should be Empty: