Credit Card
Rules and Regulations
Test contains 50 questions
You must score 80% or higher to pass
The test is in English only
ASTM E1155
You have a total of two attempts per purchase
There is no time limit for completing the test
Back
Next
*
First Name
Last Name
Email
*
example@example.com
Phone Number
Please enter a valid phone number.
Format: (000) 000-0000.
*
Company name will be used on Certificate
Company Address
*
Street Address
Street Address Line 2
City
Please Select
Alabama
Alaska
Arizona
Arkansas
California
Colorado
Connecticut
Delaware
District of Columbia
Florida
Georgia
Hawaii
Idaho
Illinois
Indiana
Iowa
Kansas
Kentucky
Louisiana
Maine
Maryland
Massachusetts
Michigan
Minnesota
Mississippi
Missouri
Montana
Nebraska
Nevada
New Hampshire
New Jersey
New Mexico
New York
North Carolina
North Dakota
Ohio
Oklahoma
Oregon
Pennsylvania
Rhode Island
South Carolina
South Dakota
Tennessee
Texas
Utah
Vermont
Virginia
Washington
West Virginia
Wisconsin
Wyoming
State
Zip Code
This section will test your knowledge of ASTM 1155
1. Is the Axiom 1155 a Type 1 or Type 2 device
*
Type 1
Type 2
2. True or False: ASTM 1155 only outlines the method by which a random traffic floor is measured.
*
True
False
3. Nmin is the minimum amount of what?
*
Q Values
P Values
Z Values
4. Referencing the image below, what option best describes it.
*
Floor Flatness
Floor Levelness
Floor Elevation
5. Which word best describes Q values?
*
Curve
Elevation
Straight
6. When determining Nmin for a 3,000 square foot test section, what equation do you use?
*
Nmin = Area / 30
Nmin = 2√Area
Nmin = Area X 3.14
7. Which word best describes Z Values
*
Curve
Elevation
Straight
8. What is the Nmin for a 10,000 square feet test section?
*
569
275
334
697
9. How many Z Values do you get when you measure a 50 foot long run.
*
50
62
41
10. Referencing the image below, when a project has two surfaces which have different overall F numbers specified. What will you need to do when testing.
*
Nothing. You can test this whole project as if it was one job and just report the results accordingly.
You will need to break this job into two Surfaces and the overall results for each section measured within each individual surface will be reported for each surface individually.
An average of the each FF and FL number will need to be taken across both surfaces and the section measurements will need to fall within this average.
11. When measuring a test section, which is not a rule.
*
A test section cannot measure less than 320 square feet
A test section can only be a rectangle or a square
Cannot have a side which measures less than 8 feet in length
Not associated with other test sections such that the test sections overlap.
Shall not cross a construction joint.
12. Does ASTM set a limit to how large a test section you can measure.
*
Yes
No
13. Per ASTM 1155 run rules, what is the minimum length of a run.
*
20 Feet
11 Feet
15 Feet
21 Feet
14. Is there a situation when a run can be placed within 2 feet of a slab boundary, construction joint, isolation joint, block out or penetration?
*
Yes
No
15. Once a run has been taken, under what circumstance can it be excluded from the final results.
*
When the FF and FL numbers for the section are not meeting the specified overall or minimum local FF and FL numbers?
When it is demonstrated that the test apparatus has reported inaccurate values or that the test procedure of this method was not followed.
16. When collecting runs using the Perpendicular and Parallel run layout method, which statement is not true?
*
Runs are of equal aggregate length in both directions.
The number of runs in each direction do not have to be equal.
Perpendicular and Parallel to the longest test section boundary.
17. Does ASTM 1155 limit how many runs you can take per test section?
*
Yes
No
18. Referencing the image below, when following the 2 foot run rule at what percentage of area excluded in a test section does the 2 foot run rule no longer apply?
*
35%
65%
50%
25%
19. True or False: A test section which has a width less than 25 feet will need to have measurement lines placed 45 degrees to the longest border.
*
True
False
20. Define minimum Local FF and FL values.
*
The lowest specified FF and FL scores that are allowable per test section.
The lowest specified FF and FL scores that are allowable per run.
The minimum amount of runs needed to locally test a section.
21. Each test should be performed within how many hours of concrete placement? (This is a rule which is defined in ACI 117-90 which ASTM 1155 refers to.)
*
53
125
72
22. Using the 45 degree run layout method, all runs need to be of equal number and equal aggregate length.
*
True
False
23. ASTM 1155 allows for different kinds of devices to be used to gather the measurement data. The inaccuracies of the device or method used to gather the data will always result in lower F-numbers as compared to a device or method which is more accurate when measuring the exact same locations.
*
True
False
24. Section test results are reported at what confidence interval?
*
50%
75%
90%
100%
25. The make model and serial number of the test apparatus used must be included in the results report.
*
True
False
Back
Next
Axiom 1155 Equipment
This section represents your knowledge of how to use the Axiom 1155, FF/FL app, and the Report Generator
1. What is the recommended minimum time that the Axiom must be powered on BEFORE performing a field calibration?
30 seconds
1 minute
There's no recommendation
2 minutes
2. Referencing the image below, why is the "Measure Job" button greyed out?
*
Axiom has not been warmed up enough
Android device and Axiom device haven't been paired
There is no Job file loaded
Need to perform a field calibration first
3. Referencing the image below, What is wrong with the file name entered?
*
The use of special characters
File name is too short
File name is too long
The use of numbers
4. When starting a run and taking the first measurement point, where should the foot pad (on the kickstand side) be in relation to you?
*
It's the closest foot to me.
It's the farthest foot from me.
Orientation does not matter.
5. Referencing the image below, in the Measuring screen. Why is the Floor Levelness value displaying 0.00?
*
No FL data has been taken.
The app displays the FL values until the end of the Run.
Not enough measurement points has been taken.
6. If you mistakenly taken a measurement point and want to delete it. Does the Axiom app allow it?
*
No. This is something you need to do in the Report Generator.
Yes. Long press the Measure button and you will be prompted to delete your last point.
Yes. Press on the Trash can icon on the Measuring Screen.
No. Go into the file manager on the phone and delete from there
7. True or False: The Axiom FF/FL app mode will allow you to save runs that are less than 11 feet long.
*
True
False
8. True or False: It it required for you to enter a run length number for each of the Runs
*
True
False
9. Referencing the image below, on the "Open Job" screen, how do you Rename or Delete an existing job file.
*
Press and Hold on the corresponding job file name
Press the 3 vertical dots and select accordingly
Press the "Sort by" then select from the drop-down menu
10. Does the Axiom 1155 equipment need to be sent back to the manufacturer for a yearly calibration?
*
Yes
No
11. Referencing the image below, once all the runs have been collected, what's required for the app to calculate the Overall FF/FL values.
*
Take more Runs
Meet a required number of FF/FL value per Run
Enter the Sqft for each Section(s)
12. Referencing the image below, what's the purpose for the icon to flip while taking measurements?
*
The orientation that the Axiom needs to be in before pressing Measure.
It doesn't flip
The orientation of the Axiom in relation to East, West, North, or South.
13. Which of the following is NOT one of the two essential features a device (such as a cell phone or tablet) must have to run apps and collect measurement data with an Axiom 1155?
*
Bluetooth
Android Operating System
Large storage size
14. When using the Axiom Toolkit app or the Layout Companion app, what is the warning that it displays prior to opening the App?
*
You agree that the usage of this App should not replace a proper understanding of ASTM E1155.
You agree that by using this App you are the rightful owner of an Axiom 1155.
There is no warning
15. Where are the batteries located for the Axiom 1155?
*
Inside the Handle assembly
Inside the Axiom assembly
16. How many and what kind of batteries does the Axiom 1155 use?
*
5-AAA
6-AA
2-C
3-D
17. Prior to calibrating the Axiom, which statement is false?
*
The Axiom foot pads need to be free of debris
Calibration needs to be done on a smooth flat surface
The Axiom has warmed up for a minimum of 3 minutes
A calibration code needs to be entered to allow for calibration
18. When taking measurements, when is a run saved and stored as a completed run?
*
Once you press Done on the Run Length prompt or press Stop
Once you close the job file, you will get prompted to save
Once you exit the Toolkit app completely you will get prompted to save
19. Where can the Apps for the Axiom 1155 be downloaded from?
*
It comes pre-loaded on the phone that comes with the Axiom and its the only way to get them.
iTunes
Google Play Store
Amazon
20. When the small blue light next to the green light is illuminated on the Axiom what does it mean?
*
The Axiom 1155 was successfully calibrated.
The Axiom 1155's batteries are fully charged.
The phone or tablet is connected via Bluetooth to the Axiom.
21. What are the unlock codes used for?
*
They unlock specific features to an individual Axiom 1155.
They unlock all functionality for any Axiom 1155.
22. Referencing the image below, when using the 1155 Report Generator under the Report Details tab, what does this Import/Replace Data File button do?
*
It overwrites all of the contact info with new contact info.
It imports a specific project file which contains measurement data taken with the Axiom 1155.
23. Referencing the image below, In this example of the Table of Results in the Report Generator the overall FF/FL numbers for Surface 1 have yet to calculate. Why?
*
Not enough measurement data was collected in order to calculate the overall FF/FL.
Because the Area of each section still needs to be entered, and once it is, the overalls will automatically calculate.
24. Prior to taking each Run, it's good practice to do what?
*
Inspect the foot pads to make sure there is no debris sticking to either of them.
Sweep the floor clean of debris along the line that you are taking the run measurements on.
Make sure the kickstand is not engaged so as to impede the movement of the Axiom.
All of the above choices are good practice.
25. Where is the Serial number located on the Axiom 1155?
*
It can be found in the settings of the Measurement App.
It's located on a sticker on the side of the handle.
It's located on the underside of the Axiom 1155.
Score