Test Firing Nova Series LPSU

Test Firing Nova Series LPSU

Please follow the steps carefully to test fire your LPSU and report your findings in the ticket. Please do not attempt this procedure unless you have been directed by support to do so.
  • 1
    Please carefully read and understand this important information
    Press
    Enter
  • 2
    Press
    Enter
  • 3
    Press
    Enter
  • 4

     Overview

     Here is what we are going to do, in summary:

    1. De-energize the system and locate the laser power supply (LPSU)
    2. Locate the green 6 pin connector/opto-board
    3. Remove the green 6 pin connector/opto-board from the LPSU
    4. Re-Energize the system
    5. Press the red test button on the LPSU and note the value on the meter

     

    This tool will walk you through each step, and the team is ready to assist should this diagnostic prove inconclusive. Just report back in the ticket with the issue.

    Press
    Enter
  • 5

    We will need to gather some info to sucessfully complete this procedure.

    Here is what we need to know: 

     

    • Location and identification of the laser power supply and optoisolator board

    Prep

    Before attempting diagnostics or repairs on the machine, make sure you have all power switches off and have the machine power cable removed from its outlet, so the system is completely deenergized. And take before pics always.

    If this test is a success, the laser beam power will be emitted. Precautions should be taken such as closing all the other machine doors and removing objects from the path of the laser beam prior to the test. Also make sure your chiller is on and pumping chilled water as this test can bypass the Water Protection as well.

    Press
    Enter
  • 6

    LPSU Location

     All Nova series machines except Nova 24 have the LPSU mounted behind the doors on the BACK of the machine. The opto board is conected to the LPSU:

    The Nova 24 LPSU is on the LEFT side. The opto board is conected to the LPSU:

    Be sure to de-energize the system

    Press
    Enter
  • 7

    Remove Optoisolator

    With the system de-energized, carefully remove the green 6 pin connector and opto-isolator.

    Press
    Enter
  • 8

    Now let's re-energize the system (the MAIN, LASER, and CHILLER switched must all be in the ON position) and press the red test button long enough to get a reading on the currennt meter.

    Note that current value and report it back to the tech team in your ticket.

    Press
    Enter
  • 9
    Would you mind providing feedback (negative and positive) about this resource, please?
    Please Select
    • Please Select
    • Sure, I would love to
    • Not now, I have work to do
    Press
    Enter
  • 10
    Please provide your feedback below
    • Huge
    • Large
    • Normal
    • Small
    Ok
    quoteCreated with Sketch.
    Ok
    Press
    Enter
  • 11

    The diagnostic will now exit and direct you to our knowledge base. 

    Please report the findings of this test in your support ticket. Thanks.